Welcome to visit DINIS amusement rides

Detail maintenance of self-control plane

Self control plane is composed of mechanical, pneumatic and oil/pressure and electrical systems, it is a kind of popular park equipment, and very welcomed by investors. What should you pay attention to when operate business? In fact, the daily maintenance is very important.The details are as follows.

1.the  maintenance of mechanical system.

  1. Check whether the fasteners of the base parts, rotating turntable parts and big arm parts are loose at lease once a week, and tighten them strictly according to the requirements.
  2. Periodically check whether the gas path system is normal.
  3. Grease should be added to arm bearings and cylinder bearings every half a month.
  4. Monthly inspection of the welding seam of the base parts, the welding seam of the rotary table parts and the connecting welding seam of the big arm parts.
  5. The whole machine should be painted every year to prevent corrosion.
  6. Power system maintenance
  7. The gear and rotary support shall be refueled several times a month to keep good lubrication.
  8. Check the gear wear regularly.
  9. Regularly check and adjust the output pressure of the air compressor: 0.8Mpa
  10. the maintenance of electrical system
  11. Check whether the power input line and the motor lead line are damaged every month, and whether the wiring terminals of the power distribution cabinet and console are firm. If any damage or loosening is found, notify the professional electrician for maintenance.
  12. The insulation resistance of the motor should be tested regularly every six months, and the insulation resistance value should not be less than 1MQ.
  13. The ground resistance value of the electrical equipment of the distribution cabinet and the console shall be regularly tested every six months. The ground resistance value shall not be greater than 1MQ.
  14. Inverter maintenance: keep dry ventilation of control room and console.

Check the main power distribution cabinet, control box and other electrical facilities regularly to make sure that they are clean and dust-free (dust blowing with tools), water free, control box panel button switches and corresponding marks intact, flexible and reliable action.

Note: when checking and cleaning the electrical box (cabinet), the main power should be cut off, and it should be carried out by qualified gas repair personnel.